Error codes Ergoline, Soltron

Why is my Ergoline or Soltron tanning unit displaying an E001?

Ergoline professional sunbeds with innovative technology.

ERROR CODES ERGOLINE

Visit our technical service – https://bestsunbeds.co.uk/content/7-sunbed-service-sunbed-repairs



Error code Fault / Fault description

Solution
E001 Condensation tank full
(Fault display only possible with the original condensation tank)
Empty the condensation tank.
E002 Condensation pump fault/Condensation water seepage
E003 Air conditioning system (device cooling ) over pressure switch
E004 Pressure controller +B24 air conditioning pressure exceeded
E005 Climatronic temperature sensor (air conditioning system)
E006 Temperature sensor: Body air
E010 Temperature limiter facial tanner
E011 Canopy temperature limiter
E012 Base temperature limiter
E013 Temperature sensor: Canopy outlet air
E014 Temperature sensor: Supply air
E015 Temperature sensor: Device cooling air circulation
E016 Temperature sensor: Air conditioning condenser
E017 Temperature sensor circulation air, air inlet
E018 Temperature of UV low pressure lamps lower than ambient temperature
E019 Temperature of UV low pressure lamps at least 30 °C higher than ambient temperature
E020 Filter panel rear and middle canopy facial tanner (FT1 & FT2)
E021 Filter panel front facial tanner
serviceCall for service. Our best engineers will help you! Just give us a call on: 01865 718485

E022 Filter panel facial tanner in side section
E023 Filter panel facial tanner canopy and side
E024 Filter panel facial tanner in canopy
Check the filter panels are correctly seated.

E025 Filter panel facial tanner rear, middle and front as well as side section
E026 Filter panel facial tanner 5-12
E027 Filter panel rear facial tanner
E028 Filter panel middle facial tanner
E029 Time overrun monitoring the high pressure units
E030 Panel switch canopy acrylic cover
(for the Ergoline Avantgarde with decorative panel)
serviceCall for service. Our best engineers will help you! Just give us a call on: 01865 718485

E030 Vertical tanner: Safety switch on the 2 left doors
Check doors

E031 Wafer switch: Plexiglass bed base or well base
Check whether the plexiglass bed base and the well are correctly locked.

E031 Vertical tanner: Safety switch on the 2 right doors
Check doors.

E032 Panel switch acrylic covers canopy/base
(Ergoline Premium: shoulder tanner, tank, front panel)
serviceCall for service. Our best engineers will help you! Just give us a call on: 01865 718485
E034 Panel switch acrylic cover canopy/side section/base/shoulder tanner/base tankCheck whether the acryliccovers canopy/side
section/base/shoulder tanner and the tank are
correctly closed/locked.

E035 Panel switch acrylic cover canopy/side section/base/shoulder tanner
Check whether the acryliccovers canopy/side section/shoulder tanner are correctly closed/ locked.

E036 Panel switch acrylic cover base or base tank
E037 Panel switch acrylic cover canopy/side section Check whether the acrylic cover canopy/side
section are correctly closed/locked.
Check whether the tank is correctly locked.

E038 Safety switch base and tank
Check whether the base and tank are correctly closed/locked.

E039 Safety switch shoulder tanner
E040 Air flow switch does not switch on with the fan running
E041 Air flow switch does not switch off 1 minute after switching off of the fan
E042 Warning, raising of the minimum speed of the main fan by 10 %
E050 Safety switch: Front panel
E051 Safety switch: Rear panel
E052 Fault: Opening mechanism
on the reflector arm (end position not reached within 45 seconds)
E053 Safety switch UV high pressure lamps in the head area
E054 Safety switch UV high pressure lamps in the foot area
E055 Fault (temperature limiter) Facial tanner 1 front
E056 Fault (temperature limiter) Facial tanner 2 rear
E057 Fault (temperature limiter) Facial tanner front
E058 Fault (temperature limiter) Facial tanner middle
E059 Fault (temperature limiter) Facial tanner rear
E060 Fault (temperature limiter) Facial tanner side section
E061 Panel switch canopy acrylic cover, decorative trim panel or temperature limiter
E062 Panel switch acrylic cover base/side section
E063 Panel switch acrylic cover side section has triggered
E064 Panel switch decorative trim panel has triggered
E065 Panel switch canopy acrylic cover has triggered
E066 Fault acrylic glass panel canopy and/or temperature fuse
E070 Fault (temperature limiter) High pressure unit 1 *
E071 Fault (temperature limiter) High pressure unit 2 *
E072 Fault (temperature limiter) High pressure unit 3 *
E073 Fault (temperature limiter) High pressure unit 4 *
E074 Fault (temperature limiter) High pressure unit 5 *
E075 Fault (temperature limiter) High pressure unit 6 *
E076 Fault (temperature limiter) High pressure unit 7 *
serviceCall for service. Our best engineers will help you! Just give us a call on: 01865 718485

E077 Fault (temperature limiter) High pressure unit 8 *

E078 Fault (temperature limiter) High pressure unit 9 *

E079 Fault (temperature limiter) High pressure unit 10 *

E080 Fault (temperature limiter) High pressure unit 11 *
E081 Fault (temperature limiter) High pressure unit 12 *
E082 Fault (temperature limiter) High pressure unit 13 *
E083 Fault (temperature limiter) High pressure unit 14 *
E084 Fault (temperature limiter) High pressure unit 15 *
E085 Fault (temperature limiter) High pressure unit 16 *
serviceCall for service. Our best engineers will help you! Just give us a call on: 01865 718485

E086 Monitor switched off by overheating protection
Allow monitor to cool for approx. 2 hours. Then restart MULTIVISION box.

E090 Exceeding of the emergency shut-down time
E091 Equipment bus fault
E092 Wiring or voltage fault in the safety circuits
E095 Auxiliary controller
E097 Voltage error 5V electronics
E098 Voltage error 12V electronics
E099 Voltage error 24V electronics
E100 Exceeding of the emergency shut-down time
E101 Equipment bus fault
E102 Wiring or voltage fault in the safety circuits
serviceCall for service. Our best engineers will help you! Just give us a call on: 01865 718485
E103 Fault in the music unit
CD-/Chip- or drive fault
Check whether the CDs or the chip are correctly
inserted/present.

E104 Chip card incorrectly inserted, defective or of the incorrect type, expired
/Check for correct seating of the chip card.
Check the remaining operating time of the UV lamps and the operating hours.

E105 Auxiliary controller
E106 Heating controller
E107 Controller facial tanner regulation
E108 Speed control 1
E109 Speed control 2
E110 Ergoline / Sunangel / Beauty Angel
Controller AQUA FRESH (AQUA SYSTEM) and AROMA
Soltron
Controller VITALIZER (AQUA SYSTEM) and AROMA
E111 Audio amplifier
E112 Channel selection
E113 Real time clock
E114 Parameter memory/device pass certificate
E115 Electronic ballast controller
E116 Controller high pressure units regulation
E117 No data transfer between sunbed and MULTIVISION box
serviceCall for service. Our best engineers will help you! Just give us a call on: 01865 718485
E118 No data transfer between sunbed and MULTIVISION boxCheck for correct seating of plug connections to the MULTIVISION box

E119 Display unit missing or not ready for operation
serviceCall for service. Our best engineers will help you! Just give us a call on: 01865 718485
E120 Sensor missing or not ready for operationCheck that the sensor is present and correctly connected to the base station. Check the power supply to the base station.

E121 Sensor must be calibrated
Calibrate the sensor (see instruction manual).

E122 Sensor calibration failed, sensor defective/dirty/
Check and clean the sensor window. Refit the sensor in the base station. Repeat this process
if necessary. Then recalibrate the sensor (see sunbed instruction manual). Check to see if the correct calibration surface was used. The calib-
ration surface must not be soiled.

E123 Plausibility test fails (sensor defective/dirty, base station defective/dirty)
Check and clean the sensor window and the base station. Refit the sensor in the base sta tion. Check that the sensor is correctly seated in the base station. Repeat this process if necessary. If plausibility testing is not successful, the sensor must be calibrated (see sunbed instruc-
tion manual).

E124 Sensor faulty
E125 Internal sensor error
serviceCall for service. Our best engineers will help you! Just give us a call on: 01865 718485
E126 One or more mains power supply phases are missing
Check the main fuse.
E128 Tanning interrupted because of low voltage Confirm the error and restart the device.

E130 Controller assembled wrongly
E131 Data communication with auxiliary controller faulty
E132 Start-up inspection of UV sources faulty
E133 Switch function auxiliary controller rotation speed control
E134 Rotation speed control fuse faulty
E135 Rotation speed control power supply faulty
E140 Main contactor does not switch on
E141 Main contactor does not switch off
E142 Switch cycle of main contactor faulty
E143 Coin box inputs different
E150 Fault in the high pressure units (1-3) in series [A] (filter panels, temperature limiter) **
E151 Fault in the high pressure units (4-6) in series [A] (filter panels, temperature limiter) **
E152 Fault in the high pressure units (7-9) in series [B] (filter panels, temperature limiter) **
E153 Fault in the high pressure units (10-12) in series [B] (filter panels,
temperature limiter) **
E154 Fault in the high pressure units (13-15) in series [C] (filter panels,
temperature limiter) **
E155 Fault in the high pressure units (16-18) in series [C] (filter panels,
temperature limiter) **
E156 Fault in the high pressure units (19-21) in series [D] (filter panels,
temperature limiter) **
E157 Fault in the high pressure units (22-24) in series [D] (filter panels,
temperature limiter) **
E158 Fault in the high pressure units (25-27) in series [E] (filter panels,
temperature limiter) **
serviceCall for service. Our best engineers will help you! Just give us a call on: 01865 718485

E159 Fault in the high pressure units (28-30) in series [E] (filter panels,
temperature limiter) **

E160 Panel switch of the acrylic cover (1-6) in series [A] **

E161 Panel switch of the acrylic cover (7-12) in series [B] **

E162 Panel switch of the acrylic cover (13-18) in series [C] **
E163 Panel switch of the acrylic cover (19-24) in series [D] **
E164 Panel switch of the acrylic cover (25-30) in series [E] **
E165 Fault in the high pressure units (1-3) (filter panels, temperature limiter), Panel switch of the acrylic cover ***
E166 Fault in the high pressure units (5-7)
(filter panels, temperature limiter), Panel switch of the acrylic cover ***
E167 Fault in the high pressure unit (4) (filter panels, temperature limiter) ***
E168 Fault in the high pressure unit (8) (filter panels, temperature limiter) ***
E170 No voltage to the fan inputs on the control board
E190 Missing languages in control unit
E191 Missing languages in audio controller
E192 Timer mode active
E199 Fatal error
E200 Fault with the fan on the electronics mount E201 Faulty program
serviceCall for service. Our best engineers will help you! Just give us a call on: 01865 718485
E202 Error during software updateRepeat the update process.
E203 Faulty Voice GuideRepeat the update process.
E204 Operator identification missingserviceCall for service. Our best engineers will help you! Just give us a call on: 01865 718485
Error codes
Error codes
Error codes

Error Codes


Additional alarms:

AlarmFault/Malfunction descriptionSolution
40 °CSupply air temperature over 40 °C Call for service.
50 °CCirculation air or lamp temperature over 50 °C Call for service.
25 bDevice air conditioning pressure over 25 bar Call for service.
doorVertical tanner door openCheck door.

5 thoughts on “Error codes Ergoline, Soltron

  • 26th May 2021 at 5:23 pm
    Permalink

    I savour, cause I found just what I used to be looking for.
    You’ve ended my 4 day lengthy hunt! God Bless you man. Have
    a nice day. Bye

    Reply
  • 20th June 2021 at 12:47 pm
    Permalink

    what does error code 08 mean for ergoline advantage 400 turbo power? it’s displayed as ‘er.08’ thanks!

    Reply
  • 10th May 2022 at 4:35 pm
    Permalink

    Ergoline lounge not starting i.e tanning tubes not illuminating, not showing an error code , can anyone help

    Reply
    • 25th May 2022 at 2:57 pm
      Permalink

      Hi, thank you for the comment.
      We are sorry you are experiencing issues with your sunbed.
      Please give us a call on 01865 718485 and one of our technicians will be able to help you.

      All the best!
      Best Sunbeds Ltd Team

      Reply
  • 2nd October 2023 at 8:58 pm
    Permalink

    Bonsoir que signifie le code erreur e57 sur machine à uv ergoline sun 550