Help CenterNews

Error Codes Luxura

Problems with your sunbed? No worries! Below is our list of Luxura Error Codes.

Lumina C / E

Code Description possible problem / solution
OVR Overrule: relais on main print defect Change main print
ERR Error airflow switch fan in bench Airflow switch not connected or defect
Fan in bench does not work >> check wiring
Airflow switch does not come in normally > airflow blocked. Exhaust pipe too long / sharp angles
PHS Phase failure Phase (L1,L2,L3 ) missing >> check wiring, check fuses
Phase sensor on main print defect >> change main print

CON Communication failure Check data cable connection between display print and main print
Change data cable or display print or main print
Blank display no display and fan in bench keeps working One of the blue filters (glass filter switch) is not closed correctly
The temperature sensor (clixon) in the canopy is measuring high temp. >> check fan in canopy
Too high temperature measured in canopy >> check exhaust pipe (too long / sharp angles)
Data cable on display print not connected well

Luxura X3

Code Description possible problem / solution
OVROverrule: relais on main print defectChange main print
   
ERRError airflow switch fan in benchAirflow switch not connected or defect
  Fan in bench does not work >> check wiring
  Airflow switch does not come in normally > airflow blocked. Exhaust pipe too long / sharp angles
   
PHSPhase failurePhase (L1,L2,L3 ) missing >> check wiring, check fuses
  Phase sensor on main print defect >> change main print
   
CONCommunication failureCheck data cable connection between display print and main print
  Change data cable or display print or main print
   
Blank displayno display and fan in bench keeps workingOne of the blue filters (glass filter switch) is not closed correctly
  The temperature sensor (clixon) in the canopy is measuring high temp. >> check fan in canopy
  Too high temperature measured in canopy >> check exhaust pipe (too long / sharp angles)
  Data cable on display print not connected well

Luxura X5, X7

Code Description possible problem / solution
E1Overrule: relais on main print defectChange main print
E2Error airflow switch fan in benchAirflow switch not connected or defect
  Fan in bench does not work >> check wiring
  Airflow switch does not come in normally > airflow blocked. Exhaust pipe too long / sharp angles
   
E6Phase failurePhase (L1,L2,L3 ) missing >> check wiring, check fuses
  Phase sensor on main print defect >> change main print
   
E3Communication failureCheck data cable connection between display print and main print
  Change data cable or display print or main print
   
Blank displayno display and fan in bench keeps workingOne of the blue filters (glass filter switch) is not closed correctly
  The temperature sensor (clixon) in the canopy is measuring high temp. >> check fan in canopy
  Too high temperature measured in canopy >> check exhaust pipe (too long / sharp angles)
  Data cable on display print not connected well
Airco serviceAirconditioning problemCondenswater in jerrycan has reached high level >> empty the jerrycan
  Levelswitch in jerrycan not working correctly >> check working 
Stop button blinkingGeneral failure messagePush the stop button and the display shows the error / message

Luxura X10

Code Description possible problem / solution
Relais Failure + no. Overrule: relais on main print defect Change main print, number behind the message is the defective relais on the main print
Wind sensor failure Error airflow switch fan in bench Airflow switch not connected or defect
Fan in bench does not work >> check wiring
Airflow switch does not come in normally > airflow blocked. Exhaust pipe too long / sharp angles
Facial tanner service Problem in the facial burner area One of the blue filters (glass filter switch) is not closed correctly or defect
Communication failure Communication failure Check data cable connection between display print and main print
Change data cable or display print or main print

Error overrule relay Overrule relais defect Overrule relais K14 defect >> change main print
Error Microcontroller Microcontroller defect One of the microcontrollers defect >> change main print
LF Controller LF Controller defect LF Controller (U9) on main print defect >> change main print
SC1 Controller SC1 Controller defect SC1 Controller (U10) on main print defect >> change main print
SC2 Controller SC2 Controller defect SC2 Controller (U7) on main print defect >> change main print
SC3 Controller SC3 Controller defect SC3 Controller (U5) on main print defect >> change main print

Luxura V5,V7

Code Description possible problem / solution
E0 Unknown display Check the display print on correct version
E1 Relais failure defective relais on main print >> change main print
E2 Temperature failure The temperature sensor (clixon) in the doors are measuring high temp. >> check fans roof
The temperature sensor (clixon) in one of the doors is defect
Doors are not closed during the session
E3
Communication failure Check data cable connection between display print and main print
Change data cable or display print or main print
E4 Main print failure Sense controller on main print defect >> change main print

Luxura V10

Code Description possible problem / solution
E1 Overrule: relais on main print defect Change main print
E2 Communication failure Check data cable connection between display print and main print
Change data cable or display print or main print
E3 Relais failure defective relais on main print >> change main print
Close doors Doorswitch not closed (one is positioned in the service door, one on top of the right door)
The temperature sensor (clixon) in the doors are measuring high temp. >> check fans roof
The temperature sensor (clixon) in one of the doors is defect
One of the blue filters (glass filter switch) in the doors is not closed correctly or defect

Seecret C500 /C700 Check working mainfan

Code Description possible problem / solution
E1 Overrule: relais on main print defect Change main print
E2 Error airflow switch fan in bench Airflow switch not connected or defect
Fan in bench does not work >> check wiring
Airflow switch does not come in normally > airflow blocked. Exhaust pipe too long / sharp angles
E3 Communication failure Check data cable connection between display print and main print
Change data cable or display print or main print
E5 Maximum Temperature NTC Heating PCB Check NTC element on Endcover feet side
Check working bodycoolerfan
E6 Phase failure One of the three phases is missing ?
E9 Maximum Temperature NTC Fan PCB Bench Check NTC element on Fan PCB frontpanel bench
Check working mainfan
E10 Maximum Temperature NTC Fan PCB Canopy Check NTC element on Fan PCB in canopy
Check working Canopy fan
E11 No communication with Fan PCB Bench Check datacables or defective Fan PCB
E12 No communication with Fan PCB Canopy Check datacables or defective Fan PCB

Luxura error

Best Sunbeds Web-store
Best Sunbeds Blog

8 thoughts on “Error Codes Luxura

  • Asgeir Sæther

    Do you have wiring drawings for luxura x7 bling? I bought one that was taken a part, and need to mount i back together

    Reply
  • Belbaki

    Bonjour,
    J’ai une luxura X7 qui affiche le message d’erreur suivant :
    E3
    SH
    B2.4
    Pourriez-vous m’aider s’il vous plaît ?

    Reply
  • Elizabeth A Karstensen

    I have a Stand Up Yellow Sun Pro Luxura V7 tanning bed. When you turn it on at it starts after a minute or 2 it stops shuts off and turns back on..is it possible it’s over heating?

    Reply
    • Julita

      Hi Elizabeth, thank you for your comment. Please send us an email over to service@bestsunbeds.co.uk and our service team will be able to assist you. Hope this helps. We wish you all the best, Best Sunbeds Team.

      Reply
  • Jochem Bos

    My Hapro Lumina (the standing model) suddenly turned off while it was in use. Also the cooling fan that should be working for some minutes after you turned it off didn’t stay on.
    The display still works, but the start button doesn’t react anymore.

    What is the most common problem that I should search for?
    My lumina is quite old, I hope the spare-parts are still available.

    Reply
    • Hi, thank you for your comment. Please contact our service team on 01865 718485 and we will be happy to help. All the best, Best Sunbeds Team

      Reply
  • Aðalgeir Bjarki Þorsteinsson

    hi i have a Luxura x7. and it shows a E1. i have changed the main print and it still shows E1. do you have any idea what is causing the error ?

    Reply
    • Julita

      Hi. Thank you for your comment. Please get in touch with Julita on 07982620396. She will be able to help! All the best, Best Sunbeds Team

      Reply

Leave a Reply