Error Codes Luxura
Problems with your sunbed? No worries! Below is our list of Luxura Error Codes.
Lumina C / E
Code | Description | possible problem / solution |
OVR | Overrule: relais on main print defect | Change main print |
ERR | Error airflow switch fan in bench | Airflow switch not connected or defect |
Fan in bench does not work >> check wiring | ||
Airflow switch does not come in normally > airflow blocked. Exhaust pipe too long / sharp angles | ||
PHS | Phase failure | Phase (L1,L2,L3 ) missing >> check wiring, check fuses |
Phase sensor on main print defect >> change main print | ||
CON | Communication failure | Check data cable connection between display print and main print |
Change data cable or display print or main print | ||
Blank display | no display and fan in bench keeps working | One of the blue filters (glass filter switch) is not closed correctly |
The temperature sensor (clixon) in the canopy is measuring high temp. >> check fan in canopy | ||
Too high temperature measured in canopy >> check exhaust pipe (too long / sharp angles) | ||
Data cable on display print not connected well |
Luxura X3
Code | Description | possible problem / solution |
OVR | Overrule: relais on main print defect | Change main print |
ERR | Error airflow switch fan in bench | Airflow switch not connected or defect |
Fan in bench does not work >> check wiring | ||
Airflow switch does not come in normally > airflow blocked. Exhaust pipe too long / sharp angles | ||
PHS | Phase failure | Phase (L1,L2,L3 ) missing >> check wiring, check fuses |
Phase sensor on main print defect >> change main print | ||
CON | Communication failure | Check data cable connection between display print and main print |
Change data cable or display print or main print | ||
Blank display | no display and fan in bench keeps working | One of the blue filters (glass filter switch) is not closed correctly |
The temperature sensor (clixon) in the canopy is measuring high temp. >> check fan in canopy | ||
Too high temperature measured in canopy >> check exhaust pipe (too long / sharp angles) | ||
Data cable on display print not connected well |
Luxura X5, X7
Code | Description | possible problem / solution | |
E1 | Overrule: relais on main print defect | Change main print | |
E2 | Error airflow switch fan in bench | Airflow switch not connected or defect | |
Fan in bench does not work >> check wiring | |||
Airflow switch does not come in normally > airflow blocked. Exhaust pipe too long / sharp angles | |||
E6 | Phase failure | Phase (L1,L2,L3 ) missing >> check wiring, check fuses | |
Phase sensor on main print defect >> change main print | |||
E3 | Communication failure | Check data cable connection between display print and main print | |
Change data cable or display print or main print | |||
Blank display | no display and fan in bench keeps working | One of the blue filters (glass filter switch) is not closed correctly | |
The temperature sensor (clixon) in the canopy is measuring high temp. >> check fan in canopy | |||
Too high temperature measured in canopy >> check exhaust pipe (too long / sharp angles) | |||
Data cable on display print not connected well | |||
Airco service | Airconditioning problem | Condenswater in jerrycan has reached high level >> empty the jerrycan | |
Levelswitch in jerrycan not working correctly >> check working | |||
Stop button blinking | General failure message | Push the stop button and the display shows the error / message |
Luxura X10
Code | Description | possible problem / solution |
Relais Failure + no. | Overrule: relais on main print defect | Change main print, number behind the message is the defective relais on the main print |
Wind sensor failure | Error airflow switch fan in bench | Airflow switch not connected or defect |
Fan in bench does not work >> check wiring | ||
Airflow switch does not come in normally > airflow blocked. Exhaust pipe too long / sharp angles | ||
Facial tanner service | Problem in the facial burner area | One of the blue filters (glass filter switch) is not closed correctly or defect |
Communication failure | Communication failure | Check data cable connection between display print and main print |
Change data cable or display print or main print | ||
Error overrule relay | Overrule relais defect | Overrule relais K14 defect >> change main print |
Error Microcontroller | Microcontroller defect | One of the microcontrollers defect >> change main print |
LF Controller | LF Controller defect | LF Controller (U9) on main print defect >> change main print |
SC1 Controller | SC1 Controller defect | SC1 Controller (U10) on main print defect >> change main print |
SC2 Controller | SC2 Controller defect | SC2 Controller (U7) on main print defect >> change main print |
SC3 Controller | SC3 Controller defect | SC3 Controller (U5) on main print defect >> change main print |
Luxura V5,V7
Code | Description | possible problem / solution |
E0 | Unknown display | Check the display print on correct version |
E1 | Relais failure | defective relais on main print >> change main print |
E2 | Temperature failure | The temperature sensor (clixon) in the doors are measuring high temp. >> check fans roof |
The temperature sensor (clixon) in one of the doors is defect | ||
Doors are not closed during the session | ||
E3 | Communication failure | Check data cable connection between display print and main print |
Change data cable or display print or main print | ||
E4 | Main print failure | Sense controller on main print defect >> change main print |
Luxura V10
Code | Description | possible problem / solution |
E1 | Overrule: relais on main print defect | Change main print |
E2 | Communication failure | Check data cable connection between display print and main print |
Change data cable or display print or main print | ||
E3 | Relais failure | defective relais on main print >> change main print |
Close doors | Doorswitch not closed (one is positioned in the service door, one on top of the right door) | |
The temperature sensor (clixon) in the doors are measuring high temp. >> check fans roof | ||
The temperature sensor (clixon) in one of the doors is defect | ||
One of the blue filters (glass filter switch) in the doors is not closed correctly or defect |
Seecret C500 /C700 Check working mainfan
Code | Description | possible problem / solution |
E1 | Overrule: relais on main print defect | Change main print |
E2 | Error airflow switch fan in bench | Airflow switch not connected or defect |
Fan in bench does not work >> check wiring | ||
Airflow switch does not come in normally > airflow blocked. Exhaust pipe too long / sharp angles | ||
E3 | Communication failure | Check data cable connection between display print and main print |
Change data cable or display print or main print | ||
E5 | Maximum Temperature NTC Heating PCB | Check NTC element on Endcover feet side |
Check working bodycoolerfan | ||
E6 | Phase failure | One of the three phases is missing ? |
E9 | Maximum Temperature NTC Fan PCB Bench | Check NTC element on Fan PCB frontpanel bench |
Check working mainfan | ||
E10 | Maximum Temperature NTC Fan PCB Canopy | Check NTC element on Fan PCB in canopy |
Check working Canopy fan | ||
E11 | No communication with Fan PCB Bench | Check datacables or defective Fan PCB |
E12 | No communication with Fan PCB Canopy | Check datacables or defective Fan PCB |
Do you have wiring drawings for luxura x7 bling? I bought one that was taken a part, and need to mount i back together
Bonjour,
J’ai une luxura X7 qui affiche le message d’erreur suivant :
E3
SH
B2.4
Pourriez-vous m’aider s’il vous plaît ?
I have a Stand Up Yellow Sun Pro Luxura V7 tanning bed. When you turn it on at it starts after a minute or 2 it stops shuts off and turns back on..is it possible it’s over heating?
Hi Elizabeth, thank you for your comment. Please send us an email over to service@bestsunbeds.co.uk and our service team will be able to assist you. Hope this helps. We wish you all the best, Best Sunbeds Team.
My Hapro Lumina (the standing model) suddenly turned off while it was in use. Also the cooling fan that should be working for some minutes after you turned it off didn’t stay on.
The display still works, but the start button doesn’t react anymore.
What is the most common problem that I should search for?
My lumina is quite old, I hope the spare-parts are still available.
Hi, thank you for your comment. Please contact our service team on 01865 718485 and we will be happy to help. All the best, Best Sunbeds Team
hi i have a Luxura x7. and it shows a E1. i have changed the main print and it still shows E1. do you have any idea what is causing the error ?
Hi. Thank you for your comment. Please get in touch with Julita on 07982620396. She will be able to help! All the best, Best Sunbeds Team